Releasing theø100 mm × 25 mm Centrifugal Fan“San Ace C100”
Featuring Industry's Top Energy-Saving and Low Noise
Industry's Top Level Large Air Flow, High Static Pressure

SANYO DENKI CO., LTD. is launching the ø100 mm × 25 mm Centrifugal Fan “San Ace C100”.
This product features Industry's top energy-saving and low noise as well as Industry's top level large air flow and high static pressure.
The product blows air in a centrifugal course, expanding its lineup of centrifugal fan series.
It is suitable for high system impedance machines, such as communications equipments, servers, storages and heat exchanges, fan filter units, clean room, medical care facilities and other applications.
Its PWM speed control function allows external fan rotation speed control. 




Features

Energy-saving

The fan features the industry’s top energy-saving performance among fans in its size at the same airflow level.
・Power consumption: 10.56 W

Low noise

The fan features the industry’s top low noise among fans in its size at the same air flow level.
・Sound Pressure Level: 60 dB(A)

Large air flow and high static pressure

The fan features the industry’s top level large air flow and high static pressure among fans in its size.
・Maximum air flow : 1.77 m3/min
・Maximum static pressure : 560 Pa

 

Specifications

Model No. 9TM48P4H01
  High-speed rotation Low-speed rotation
Air flow 1.77 m3/min (62.5 CFM) 0.51 m3/min (18.0 CFM)
Static Pressure 560 Pa (2.25 inch H2O) 48 Pa (0.19 inch H2O)
Power Consumption 10.56 W 1.92 W
Rated Speed 6,400 min-1 2,000 min-1
Sound Pressure Level 60dB(A) 34dB(A)
Size ø100mm x 25mm thick
Operating Voltage DC 36 V to 60 V
Rated Voltage DC 48V
Life Expectancy 40,000 hours
(L10: Survival rate: 90% at 60℃, rated voltage, and continuously run in a free air state)
Mass Approx.150 g

When our inlet nozzle (Option) is mounted.
Inlet nozzle: Nozzle mounted in fan inlet side to adjust the flow of introduced air

 

PDF Catalog

 

Applications

These products are specifically designed for use in communications equipment, servers, Storages, heat exchanges, fan filter units, clean room, medical care facilities and other applications.

 

Flow of air at using the fan

Referance diagram for mounting a device

 

Release Date

September 3, 2009

 

Projected sales figures

Initial fiscal year: 5,000 units per month
Second fiscal year: 10,000 units per month

 

The information in this release is current as of September 3, 2009.

“ San Ace ” is a trademark of SANYO DENKI CO.,LTD.

 

Close this page